60hz 3 phase big power open type 906kva/725kw diesel genset with Cummins KTA38-G2 and brushless Leadtech generator
Basic Info
Model No.: OCL60-1000
Product Description
2.Cummins engine kta38-g2
3.brushless 100% copper Generator
4.1 year warrenty
60hz 3 phase big power open type 906kva/725kw diesel genset with Cummins KTA38-G2 and brushless Leadtech generator advantages of 725kw diesel genset : 1. Powered by Cummins brand new engine; 2.Epuiped with brushless,self-excited,AC synchronous, single bearing Foshan Leadtech generator; 3. Independently design the silencer with thick iron ; 4.Rubber pad mountings isolate base from engine/generator assembly ; 5.Easy for installation, operation and maintenance ; 6.Low operating cost results in optional economy. Parameter of 725kw diesel genset :
Main Technical data of generator set | ||||
Model | OCL60-1000 | |||
Prime Power | 725KW/906kva | |||
Standby Power | 800KW/1000kva | |||
Rated Voltage | 110/220V | |||
Rated Current | 1376A | |||
Rated Frequency | 60HZ | |||
Rated Speed | 1800 rpm | |||
Overall Dimension | 4800*2060*2450mm | |||
Main Technical Data of Engine | ||||
Brand | CUMMINS | |||
Model | KTA38-G2 | |||
Prime Power | 809KW | |||
standby power | 895kw | |||
Governor Type | Electronic | |||
Cylinder Type | 12 cylinder in vee,direct injection | |||
Cooling Method | Water cooled | |||
Bore × Stroke | 140*152 mm | |||
Compression Ratio | 14.5:1 | |||
Displacement | 37.8L | |||
Starting Method | DC 24V electric start | |||
Fuel Consumption | ≤207g/kw.h | |||
coolant capacity | 308L | |||
fuel system | PT Fuel Injection Pump | |||
Main Technical Data of Alternator | ||||
Brand | Leadtech | |||
Model | LTG404D | |||
Prime Power | 740KW | |||
Excitation Mode | Brushless, self-exciting ,single bearing | |||
Prime Voltage | 110/220V | |||
Frequency | 60HZ | |||
Power Factor | 0.8(lagging) | |||
Phase/Wire | 3 phase 4 wires | |||
Insulation Grade | H | |||
Protection Class | IP22 | |||
Intelligent Control System | ||||
Brand:Smartgen 6110/ Smartgen 6120with ATS mould | ||||
Function:Over load protection; Generator over/under frequency protection:Generator over/under/unbalance voltage Protection Over load protection; Generator over/under frequency protection:Generator over/under/unbalance voltage Protection ,etc. | ||||
ATS(Automatic Transfer switches):optional | ||||
Function:Once the main power failure, the control panel will received the signal to start the genset within 5 seconds, ATS will switch to the load wires to connect genset power supply,and the whole process takes less than 15 seconds. After the main power recovered 30 seconds, ATS automatically switch the load wires to connect main power supply,the genset will stop after running 180 seconds. |
Product Categories : Diesel generator with famous engine